| MODEL | DS310SH | ||
| Power (kVA) | 10 | ||
| INPUT | |||
| Voltage | 380/400 VAC 3P + N + G ± 20% | ||
| Frequency | 50Hz / 60Hz, ± 10% | ||
| Power factor (at 100% load) | ≥ 0.99 | ||
| THDI (at 100% load) | ≤ 4% (depends on mains input conditions) | ||
| By-pass voltage | 380/400 VAC 3P + N, 4 Wires, ± 10% | ||
| Voltage distortion | ≤ 10% | ||
| Protection | Fuses, Voltage & Frequency Tolerance | ||
| OUTPUT | |||
| Power (kW) | 10 | ||
| Power factor (*) | 1.0 | ||
| Voltage | 380/400 VAC 3P + N, ± 1% | ||
| Frequency | 50Hz / 60Hz | ||
| Frequency tolerance | Line synchronized: ± 2% / Free running: ± 0.1% | ||
| Efficiency (at 100% load) | 94% | ||
| Crest factor | 3:1 | ||
| Overload protection (**) | 100% – 125% load: 10 min, 125% – 150% load: 1 min, – > 150% load: by pass | ||
| Protection | Fuses,Advanced short circuit, Voltage tolerance, DC balance, Regenerative load, Current limiting | ||
| Voltage THD | ≤ 2% (linear load), ≤ 5% (non-linear load) | ||
| BATTERIES | |||
| Type | VRLA AGM / GEL / NiCd | ||
| Number of batteries | 60 (± 30) batteries | ||
| Float charging voltage | ± 405 VDC (adjustable) | ||
| End of discharge voltage | ± 300 VDC (adjustable) | ||
| Battery cabinet | External (attached cabinet at the bottom of UPS) | ||
| Battery ambient temperature | 25°C | ||
| Battery protection | 3 level alarms, Battery fuses, Charging current limit, Temperature compensation (optional) | ||
| Automatic battery test | Standard: every 72 hours (adjustable) | ||
| GENERAL | |||
| Standards | EN62040-1, EN62040-2, EN62040-3 | ||
| User interface | 4 lines LCD panel, Mimic leds, 5 vector buttons, buzzer | ||
| Indicators | P-N voltage, P-P voltage, Current, Power, Crest Factor, Frequency, PF, Service Time | ||
| Advanced | Self diagnostics, 3 maintenance time indicators, Calibration over RS232,operating hour meter | ||
| Communication | RS232 serial port, 3 programmable dry contact outputs | ||
| Inputs | EPO input | ||
| Genset kit | Standard (programmable) | ||
| Software | Standard T-Mon UPS Management Software (3 clients + 1 server management) | ||
| Alarm logging | Standard: with time & date 512 events | ||
| Protection | Power module over temperature, Over current, Temperature high alarms | ||
| Operating temperature | 0°C – 40°C | ||
| Protection degree | IP20 | ||
| Relative humidity | 90% max. (non-condensing) | ||
| Altitude | < 1000m. above sea level | ||
| Acoustic noise | < 55 dBA | ||
| Weight (kg) | 47.5 | ||
| Dimensions (mm) HxWxD | 700x300x770 (without batt.) / 1170x300x800 (with 7-9ah batt.) | ||
| OPTIONS | |||
| Different input / output voltage | Please ask | ||
| Adaptors | SNMP, MODBUS, RS485, Remote panel | ||
| Software | T-Mon Admin Multi UPS monitoring 10-50-100-200 clients, T-Mon Server 50-100-200 clients | ||
| (*) Ask for 0.8 and 0.9 power factor. | |||
| (**) The waiting times for excessive loads vary depending on the ambient temperature. | |||
Fill in the order form and get a quote!