866,00 €
(kaina be PVM)
Pagrindinės funkcijos
1.STO (saugus sukimo momento išjungimas)
2.VF ir bejutiklinis vektorinis valdymas
3.Iki 0,5 Hz/150 % paleidimo momento
4.Įmontuotas stabdžių blokas ir gausios sąsajos
5.Išorinė klaviatūra parametrams kopijuoti
6.Standartiniai C3 filtrai (≥4 kW); pasirinktinai C3 filtrai (≤2,2 kW) ir C2 filtrai
7.Teikiamos pritaikymo paslaugos (pvz., PTC ir „Fire-Mode”)
8.2 metų garantija
9.UL/cUL, TUV, SUD, CE sertifikatai
Techninė specifikacija: GD20-EU Catalog(EN)-201908(V1.2)
| Function | Specification | ||
|
Power input
|
Input Voltage | 3PH 380V (-15%)~440V(+10%) | |
| Input current(A) | 47 | ||
| Input frequency (Hz) | 50 Hz or 60 Hz allowable range 47-63Hz | ||
|
Power output
|
Output motor capacity (kW) | 18.5 | |
| Output current (A) | 38 | ||
| Output voltage (V) | 0-input voltage, < error 5% | ||
| Output frequency | 0-400 Hz | ||
|
Technical control feature
|
Control mode | SVPWM, SVC | |
| Adjustable-speed ratio | 1:100 | ||
| Speed control accuracy | ± 0,2% (SVC) | ||
| Speed fluctuation | ± 0,3% (SVC) | ||
| Torque response | <20ms (SVC) | ||
| Torque control accuracy | 10% | ||
| Starting torque | 0, 5 Hz/150% (SVC) | ||
|
Overload capability
|
150% of rated current: 1 minute | ||
| 180% of rated current: 10 seconds | |||
| 200% of rated current: 1 second | |||
|
Running control feature
|
Frequency setting method
|
Digital setting, analog setting, pulse frequency setting, multi step speed running setting, simple PLC setting, PID setting, MODBUS communication setting. | |
| Shift between the set combination and set channel. | |||
| Auto-adjustment of the voltage | Keep a stable voltage automatically when the grid voltage transients | ||
| Fault protection | Provide comprehensive fault protection functions: over-current, over-voltage, under-voltage, over-heating, phase loss and overload, etc. | ||
|
Peripheral interface
|
Analog input | 1 (AI2) 0~10 V/0~20mA and 1 (AI3) -10 ~10 V | |
| Analog output | 2 (AO1, AO2) 0~10V/0~20mA (Only 1 AO for inverters≤ 2.2 kW | ||
| Digital input | 4 common inputs, the Max. frequency: 1kHz; 1 high speed input, the Max. frequency: 50kHz. | ||
| Digital output | 1 Y1 terminal output. | ||
| Relay output | 2 programmable relay outputs (only 1 relay output for inverters≤ 2.2 kW.) RO1A NO, RO1B NC, RO1C common terminal. RO2A NO, RO2B NC, RO2C common terminal. Contactor capacity: 3A/AC250V | ||
|
Others
|
Mountable method | Wall and rail mountable | |
| Breaking Unit | ≤ 37 kW built-in. 45~110 kW optional built-in (Model „-B”) | ||
| EMI filter | Optional filter: meet the degree requirement of IEC61800-3 C2, IEC61800-3 C3. | ||
|
Temperature of the running environment
|
-10~50°C | ||
| Above 40°C, derate 1% for every additional 100m. | |||
|
Altitude
|
<1000 m | ||
| Above 1000m, derate 1% for every additional 100m. | |||
| Protective degree | IP20 | ||
| Safety | Meet the requirement of CE | ||
| Cooling | Fan cooling | ||
Užpildykite užsakymo formą ir gaukite pasiūlymą!